Centrifugal fans

plastic centrifugal fans for conveying chemically aggressive exhaust air

HLU’s plastic centrifugal fans are specially designed for conveying chemically aggressive exhaust air. Their distinguishing feature is their extreme resistance to corrosion. They also generate high volume flows and pressure differences with optimum efficiency. Centrifugal fans are the efficient “all-rounders” of plastic fans. HLU offers you the perfect solutions for your needs, from standard products to individual bespoke products. For use in potentially explosive areas, all series are available in an explosion-proof version for zones 2 and 1 in accordance with ATEX.
small-centrifugal-fans

Small centrifugal fans

HF R 75/110

Application
  • can be used in all applications with small air volumes
  • low weight and compact dimensions ensure easy installation
  • ideal for 24-hour exhaust air extraction from chemical storage cabinets
  • optionally suitable for installation in and extraction from ATEX zones 2 and 1 Features
Features
  • volume flow from 15 to 500 m³/h
  • at a maximum pressure difference of 420 Pa
  • available in nominal diameters 75 mm and 110 mm
centrifugal-fans

Centrifugal fans

HF R 15/17

Application
  • can be used in all applications with medium air volumes
  • ideal for extraction from fume hoods and chemical storage cabinets in laboratories
  • also suitable, with optional accessories, for more demanding industrial applications, such as tank vapour extraction in the electroplating industry
  • optionally suitable for installation in and extraction from ATEX zones 2 and 1
Features
  • volume flow from 100 to 15000 m³/h
  • at a maximum pressure difference of 5000 Pa
  • available in 12 nominal diameters from 125 to 500 mm intake diameter
centrifugal-fans-with-ec-motors

Centrifugal fans with EC motors

HF R 15/17 EC

Application
  • ideal for energy-sensitive applications and modernisation measures
  • ptionally suitable for installation in and extraction from ATEX zone 2
Features
  • volume flow from 100 to 3000 m³/h
  • at a maximum pressure difference of 1600 Pa
  • available in 6 nominal diameters from 125 to 250 mm
  • very simple speed control with EC motor with integrated control electronics
  • optional control via external 0 to 10 volt signal or Modbus interface
centrifugal-fans

Centrifugal fans

HF R 13/16

Application
  • can be used in all applications with large air volumes, such as electroplating tanks, the semiconductor industry, water treatment plants and special applications involving process exhaust air
  • ideal for extraction of collected exhaust air from large laboratories at universities, research institutes and in the chemical industry
  • the wide range of possible materials for the housings and impellers means that they can be optimally configured to meet specific requirements
  • optionally suitable for installation in and extraction from ATEX zones 2 and 1
Features
  • volume flow from 3000 to 250000 m³/h
  • at a maximum pressure difference of > 5000 Pa
  • available in 18 nominal diameters from 160 to 1600 mm intake diameter
high-pressure-fan

High-pressure fan

HF R 48

Application
  • for achieving high pressures at low flow rates
  • ideal for applications with relieving hoods, multi-stage exhaust air purification, liquid baths and many special applications involving process exhaust air
  • the wide range of possible materials for the housings and impellers means that they can be optimally configured to meet specific requirements
  • optionally suitable for installation in and extraction from ATEX zones 2 and 1
Features
  • volume flow from 100 to 7000 m³/h
  • at a maximum pressure difference of > 7000 Pa
  • available in 7 nominal diameters from 50 to 200 mm intake diameter
centrifugal-fans

Centrifugal fans

MRV/RV – 45/63

Application
  • can be used in all applications with small and medium air volumes
  • ideal for extraction from fume hoods and chemical storage cabinets in laboratories
  • also suitable, with optional accessories, for more demanding industrial applications, such as tank vapour extraction in the electroplating industry
  • optionally suitable for installation in and extraction from ATEX zones 2 and 1
Features
  • volume flow from 150 to 8000 m³/h
  • at a maximum pressure difference of 2500 Pa
  • available in 5 nominal diameters from 160 to 355 mm
centrifugal-fan

Centrifugal fan

RV 45/63

Application
  • can be used in all applications with small to high air volumes
  • ideal for extraction systems for demanding industrial applications, such as tank vapour extraction in the electroplating industry
  • optionally suitable for installation in and extraction from ATEX zones 2 and 1
Features
  • volume flow from 150 to 150000 m³/h at a maximum pressure difference of 3000 Pa
  • available in 18 nominal diameters from 160 to 1600 mm intake diameter
high-pressure-fan

High-pressure fan

RV 20

Application
  • can be used in all applications with medium air volumes
  • ideal for extraction with high pressure differences
  • also suitable, with optional accessories, for more demanding industrial applications, such as tank vapour extraction in the electroplating industry
  • optionally suitable for installation in and extraction from ATEX zones 2 and 1
Features
  • volume flow from 80 to 2500 m³/h at a maximum pressure difference of >6500 Pa
  • available in 4 nominal diameters from 80 to 140 mm intake diameter
high-pressure-fan

High-pressure fan

RV 28

Application
  • can be used in all applications with medium and high air volumes
  • ideal for extraction with high pressure differences
  • also suitable, with optional accessories, for more demanding industrial applications, such as tank vapour extraction in the electroplating industry
  • optionally suitable for installation in and extraction from ATEX zones 2 and 1
Features
  • volume flow from 500 to 50000 m³/h
  • at a maximum pressure difference of > 6000 Pa
  • available in 13 nominal diameters from 200 to 800 mm intake diameter

Overview of the possible housing positions: